JSN S2625<br />

Name Washer/Pasteurizer, Vertical Rotation, Combination<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing C | Hot water and drain<br />

Volts1 240<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 1<br />

Amps1 47<br />

Amps2 20<br />

Weight (lbs) 350 Weight (kgs) 159<br />

Height (in) 67 Height (cen) 170<br />

Width (in) 30 Width (cen) 76<br />

Depth (in) 33 Depth (cen) 84<br />

Volts2 120<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 7884<br />

Watts1 11280<br />

Watts2 2400<br />

Description<br />

Unit of Issue EA<br />

Group Sterilizers and Associated <strong>Equipment</strong><br />

A fully automatic, compact, combination, vertical rotation, washer/pasteurizer with baskets. Unit features: 30 minute wash and<br />

pasteurizing cycles, temperature recorder for pasteurizing cycle, thermostatically controlled water temperature in pasteurizing cycle; visual<br />

signal at end of cycle; power hoist; liquid level control; and a 2.5 cubic foot load capacity. Used for washing then pasteurization (a means<br />

of high-level disinfection to kill pathogenic vegetative bacteria and viruses by total immersion in water at 160°-170°F for 30 minutes) of<br />

breathing circuit parts used by respiratory care and anesthesia departments. For medium to low volume processing.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 1243 of 1462

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!