JSN X5100<br />

Name Radiographic Unit, 80 kW, Chest, Digital<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 480<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc B | Lead lined walls<br />

Phase1 3<br />

Phase2 1<br />

Amps1 120<br />

Amps2 16<br />

Weight (lbs) 1565 Weight (kgs) 711<br />

Height (in) Height (cen) 0<br />

Width (in) 146 Width (cen) 370<br />

Depth (in) Depth (cen) 0<br />

Volts2 230<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 7850<br />

Watts1 99764<br />

Watts2 3680<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Digital chest system designed solely for making x-ray exposures of the chest. Patients can be standing, seated or lying on their sides.<br />

Patient through put is approximately 60 exposures per hour. <strong>The</strong> configuration of the system consists of a detector subsystem, image<br />

processing system, 80 kW high frequency x-ray generator and ceiling suspension or floor mounted column for the x-ray tube. <strong>The</strong> system<br />

shall be DICOM 3.0 compatible, for easy linkage to filmless image management systems and review stations.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />