JSN X6240<br />

Name Radiographic Unit, Computerized Tomography (CT)<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 480<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc B | Lead lined walls<br />

Phase1 3<br />

Phase2 0<br />

Amps1 120<br />

Amps2 0<br />

Weight (lbs) 7445 Weight (kgs) 3380<br />

Height (in) 0 Height (cen) 0<br />

Width (in) 0 Width (cen) 0<br />

Depth (in) 0 Depth (cen) 0<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 47851<br />

Watts1 99764<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

<strong>The</strong> CT Scanner System is an noninvasive radiographic technique that involves the reconstruction of a tomographic plane of the body<br />

from a large number of collected x-ray absorption measurements taken during a scan around the body's periphery. <strong>The</strong> CT System shall<br />

be a single gantry, whole body scanning system appropriate to support tertiary care facilities with an annual projected workload of less<br />

than 5,500 separate studies. System includes DICOM 3.0 or latest version software protocol. System to be procured with turnkey<br />