JSN M8045<br />

Name Whirlpool, Extremity, Mobile, Large<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 8<br />

Amps2 0<br />

Weight (lbs) 170 Weight (kgs) 78<br />

Height (in) 43 Height (cen) 109<br />

Width (in) 22 Width (cen) 56<br />

Depth (in) 36 Depth (cen) 91<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 960<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Mobile extremity whirlpool for full leg and large limb hydrotherapy. Unit includes a turbine ejector and aerator for strong, precise<br />

whirlpool action, thermometer, casters and an auxiliary floor drain valve. Unit may require a ground fault interrupt power circuit and may<br />

use a thermostatic mixing valve for controlling water temperature when filling.<br />

JSN M8050<br />

Name Whirlpool, Leg, CRS, Floor Mounted<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530007104005<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 115<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc A | Earth ground<br />

Phase1 1<br />

Phase2 0<br />

Amps1 8<br />

Amps2 0<br />

Weight (lbs) 705 Weight (kgs) 320<br />

Height (in) 57 Height (cen) 145<br />

Width (in) 22 Width (cen) 56<br />

Depth (in) 42 Depth (cen) 107<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 920<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Floor mounted leg whirlpool. <strong>The</strong> whirlpool consists of a heavy gauge, leak proof, stainless steel corrosion resistant tank, an electric<br />

turbine ejector and aerator, a dial thermometer, a thermostatic water mixing console, a treatment timer and a built-in overflow lip. <strong>The</strong><br />

database height dimension includes the turbine and the database weight figure is for a filled unit.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />