JSN P2100<br />

Name Disposal, Garbage, 2 HP Motor<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4540<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 208<br />

Utility2: Electrical C | 208/220 volt<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 12<br />

Amps2 0<br />

Weight (lbs) 135 Weight (kgs) 62<br />

Height (in) 38 Height (cen) 97<br />

Width (in) 19 Width (cen) 48<br />

Depth (in) 19 Depth (cen) 48<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2496<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Plumbing Fixtures<br />

Garbage disposal. A two (2) horsepower versatile waste disposal unit suitable for facilities where 500 to 1000 meals are prepared and<br />

served daily. Requires eight (8) gallons per minute water flow rate, and outlet flange tapped for a two (2) inch pipe. Unit will have a<br />

manual reversing switch and shall comply with <strong>MIL</strong> SPEC No. <strong>MIL</strong>-G-15840. Multiple electrical configurations are available.<br />

JSN P2450<br />

Name Valve, Mixing, <strong>The</strong>rmostatic<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing A | Hot and cold water<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 0 Weight (kgs) 0<br />

Height (in) 24 Height (cen) 61<br />

Width (in) 24 Width (cen) 61<br />

Depth (in) 6 Depth (cen) 15<br />

Volts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Plumbing Fixtures<br />

<strong>The</strong>rmostatic mixing valve with washout hose. Used with portable whirlpool equipment. <strong>The</strong>rmostatic valve is used to maintain<br />

temperature between 70 and 110 degree Fahrenheit, with a flow rate of 20 gallons a minute. <strong>The</strong> washout hose assembly is used to wash<br />

out tanks after treatment. Used in physical therapy department to provide comfortable water temperature for patient treatments.<br />

Hertz<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />