JSN T8025<br />

Name Generator, Function<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6625<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 8<br />

Amps2 0<br />

Weight (lbs) 11 Weight (kgs) 5<br />

Height (in) 7 Height (cen) 18<br />

Width (in) 11 Width (cen) 29<br />

Depth (in) 18 Depth (cen) 46<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 960<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Shop <strong>Equipment</strong>/Tools<br />

Function generator. Characteristics/components include generated size, triangle and square waveforms; covers 0.2 Hz to 2.0 MHz in 7<br />

ranges; voltage controlled amplitude output; 20 dB step attenuator; four digit frequency counter display and ability to generate lowdistortion<br />

sine waves which make the unit uniquely appropriate for applications requiring audio signals.<br />

JSN T8030<br />

Name Electrosurgery Analyzer<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6625010428213<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 115<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 2<br />

Amps2 0<br />

Weight (lbs) 22 Weight (kgs) 10<br />

Height (in) 6 Height (cen) 15<br />

Width (in) 16 Width (cen) 41<br />

Depth (in) 14 Depth (cen) 36<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 230<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Shop <strong>Equipment</strong>/Tools<br />

Electrosurgery analyzer. This is a power analyzing system that verifies electrosurgical specifications such as output power, radio frequency<br />

leakage and output waveforms. This is necessary because electrosurgical units should provide safe controlled power output at RF with a<br />

predetermined physiological load so that burns and electrical shocks are avoided.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />