JSN S0965<br />

Name Washer/Disinfector, Dental<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 208<br />

Utility2: Electrical C | 208/220 volt<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 30<br />

Amps2 0<br />

Weight (lbs) 150 Weight (kgs) 68<br />

Height (in) 34 Height (cen) 86<br />

Width (in) 24 Width (cen) 61<br />

Depth (in) 24 Depth (cen) 61<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 6240<br />

Watts2<br />

Description<br />

Unit of Issue EA<br />

Group Sterilizers and Associated <strong>Equipment</strong><br />

Washer disinfector used to clean dental instruments. <strong>The</strong> unit washes, disinfects and rinses, but does not sterilize the instruments.<br />

JSN S1815<br />

Name Generator, Steam, Electric, 30 kW<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing C | Hot water and drain<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 3<br />

Amps1 15<br />

Amps2 84<br />

Weight (lbs) 550 Weight (kgs) 250<br />

Height (in) 49 Height (cen) 124<br />

Width (in) 30 Width (cen) 76<br />

Depth (in) 33 Depth (cen) 84<br />

Volts2 208<br />

Hertz 50/60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 1750<br />

Watts1 1800<br />

Watts2 30262<br />

Description<br />

Unit of Issue EA<br />

Group Sterilizers and Associated <strong>Equipment</strong><br />

An approximately 30 kW electric steam generator/boiler with low water cut-off/level control, water level sight glass, main off/on switch,<br />

pilot light, lowdown/drain valves, safety valve, and steam pressure gauge. <strong>The</strong> unit can deliver steam at operating pressures up to 90<br />

PSIG. and produce a minimum steam output of 87 lbs./hr. Unit provides condensate free steam, between 97% to 100% vapor quality,<br />

needed to power sterilizers, water stills, utensil sanitizers, and other steam powered equipment when facility supplied steam is not<br />

available. Various electrical configurations are available for the heaters, for pricing purposes 208V, 60HZ, 3PH, 84AMPS is used.<br />