05.04.2013 Views

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

JSN K3600<br />

Name Steamer, Stack, 2 Compartments, Gas Boiler<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 7310<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas A | Natural gas<br />

Utility6: Misc E | Vent to atmosphere<br />

Phase1 1<br />

Phase2 0<br />

Amps1 7<br />

Amps2 0<br />

Weight (lbs) 750 Weight (kgs) 341<br />

Height (in) 72 Height (cen) 183<br />

Width (in) 25 Width (cen) 64<br />

Depth (in) 36 Depth (cen) 91<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 200000<br />

Watts1 840<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Food Service <strong>Equipment</strong><br />

Stack steamer. <strong>The</strong> unit is made of stainless steel and features two pressureless steamer compartments above a gas fired boiler (electric<br />

boilers are available). Each compartment has its own sealed door and a switch which turns off the blower and steam supply to that<br />

compartment when the door is opened. A further safety shuts the unit off if the water level in the boiler gets too low or the steam<br />

pressure gets too high. A drip sink for catching condensation is positioned under the compartments. A side access door allows<br />

maintenance and repair of piping and other utilities. See manufacturers' installation notes for locating the drain for this unit and the<br />

required minimum clearances from combustible materials.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 646 of 1462