JSN K4230<br />

Name Mixer, Table Mounted, 20 Quart<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 7310<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 12<br />

Amps2 0<br />

Weight (lbs) 225 Weight (kgs) 103<br />

Height (in) 35 Height (cen) 89<br />

Width (in) 20 Width (cen) 51<br />

Depth (in) 27 Depth (cen) 69<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1440<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Food Service <strong>Equipment</strong><br />

Table mounted mixer with a 20 quart stainless steel bowl. <strong>The</strong> unit comes complete with beater and wire whip attachments. Some<br />

models feature timers and bowl cages. Other accessories and floor standing configurations are available. <strong>The</strong> unit is gear driven and used<br />

to prepare food in hotels, restaurants and hospital kitchen areas.<br />

JSN K4250<br />

Name Mixer, Free Standing, 30 Quart<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 7310<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 456 Weight (kgs) 207<br />

Height (in) 50 Height (cen) 127<br />

Width (in) 27 Width (cen) 69<br />

Depth (in) 36 Depth (cen) 91<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Food Service <strong>Equipment</strong><br />

Floor standing mixer with a 30 quart stainless steel bowl. <strong>The</strong> mixer has a 3/4 HP motor, hand lever bowl lift, overload protection and<br />

safety interlocks. Unit comes complete with a flat beater and a wire loop attachment. Bowl guards, other accessories and other voltage<br />

models are available. This unit is used in hospital kitchens for mixing food.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 663 of 1462

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!