JSN M3010<br />

Name Bed, Air-Fluidized<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 10<br />

Amps2 0<br />

Weight (lbs) 2050 Weight (kgs) 931<br />

Height (in) 37 Height (cen) 94<br />

Width (in) 37 Width (cen) 94<br />

Depth (in) 89 Depth (cen) 226<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1200<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Air fluidized bed consisting of a rectangular tank that contains millions of tiny soda lime glass beads (microspheres). An air compressor<br />

forces air up through the beads and a woven filter sheet. <strong>The</strong> beads' and filter sheet's resistance to the air flow creates an air dam which<br />

suspends the patient and better spreads the pressure from the patient's weight across the patient's body. <strong>The</strong> bed also features a rubber<br />

bumper guard around the tank, hand and foot operated fluidization switches, a fluidization control valve to regulate the pressure entering<br />

the tank, a main control panel with shut-off and alarm heating and cooling circuits and a digital temperature display. Used for patients<br />

who have spinal cord injuries, burns, skin grafts or open fractures. Due to the intensive service requirements for this bed, it is usually a<br />

leased (rather than purchased) piece of equipment.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />