JSN L0990<br />

Name Analyzer, Urine, Basic<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Basic urine analysis system. Automated system provides 8 chemistries. Unit requires only power connection. This unit is a benchtop<br />

instrument.<br />

JSN L0995<br />

P<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 90 Weight (kgs) 41<br />

Height (in) 21 Height (cen) 53<br />

Width (in) 20 Width (cen) 51<br />

Depth (in) 21 Depth (cen) 53<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 600<br />

Watts2 0<br />

Name Analyzer, Urine, Advanced<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Advanced urine analysis system. Automated system provides chemistry and image analysis of a batch of urine samples. Unit requires<br />

only power and a drain connection.<br />

P<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 148 Weight (kgs) 68<br />

Height (in) 26 Height (cen) 66<br />

Width (in) 29 Width (cen) 74<br />

Depth (in) 27 Depth (cen) 69<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 600<br />

Watts2 0<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />