JSN L2330<br />

Name Cabinet, Bio Safety, Class III<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc E | Vent to atmosphere<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 0 Weight (kgs) 0<br />

Height (in) 90 Height (cen) 229<br />

Width (in) 58 Width (cen) 147<br />

Depth (in) 35 Depth (cen) 89<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Class III, bio safety cabinet. <strong>The</strong> unit includes an 85 CFM blower with a variable speed power stat, a manometer mounted on box front to<br />

indicate flow, 1/4 inch safety glass viewing panel, polarized and grounded electrical outlets with indicating switches, one pair of 24 inch<br />

long neoprene gloves, one inlet filter, one absolute filter with connecting hoses, and 40" of 2" diameter exhaust hose with clamps, one<br />

fluorescent light with fixture and switch, one ultraviolet light, two grooved glove ports, one variable height mobile bench, with 5" ball<br />

bearing, toe operated, locking casters, and a 1/25 HP motor. Used for cultivation of microorganisms, serological dissections, and aerosol<br />

exposures.<br />