JSN V0072<br />

Name Rack, Ferret, 3 Tier, 6 Cages Per Rack<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 250 Weight (kgs) 114<br />

Height (in) 70 Height (cen) 178<br />

Width (in) 67 Width (cen) 170<br />

Depth (in) 33 Depth (cen) 84<br />

Volts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Veterinary<br />

Rack, ferret, 3 tier, 6 cages per rack. Stainless steel cages with #2 wire mesh in the top half of cage doors. Each rack to include 6 stainless<br />

steel refuse pans and 5 square feet of animal space. Racks are mounted on 5 inch heavy duty stainless steel casters, 2 locking.<br />

JSN V0074<br />

Hertz<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Name Rack, Rabbit, 6 Cages Per Rack<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 0 Weight (kgs) 0<br />

Height (in) 76 Height (cen) 193<br />

Width (in) 61 Width (cen) 155<br />

Depth (in) 33 Depth (cen) 84<br />

Volts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Veterinary<br />

Rack, rabbit, 3 tier, 2 cages per tier, 6 cages per rack. Racks constructed entirely of type 304 stainless steel tubing with 16 gauge wall<br />

thickness. Mounted on 5 inch heavy duty stem-type copper/nickel/chrome plated casters. Rack dimensions: 59" W x 25- 1/4" D x 71-1/2"<br />

H. Accessory items such as cages, cage floors, feeding bowls, water systems, etc. must be ordered separately.<br />

Hertz<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />