JSN E0409<br />

Name Nurse Station, Admitting, Free Standing, 72" W<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Description<br />

Unit of Issue EA<br />

Group Modular Casework<br />

Nurse Station typicals have non-powered steel frames with a pre-installed metal junction box for user defined hard-wired electrical<br />

solutions. Data modules and low voltage cabling can be routed freely within the frame. Electrical and/or data devices are not provided as<br />

part of the configuration. Panel inserts are available in fabric, painted metal, tackable, acoustical, paper management, rail, glass, open and<br />

electrical/data accessible styles. Typicals include panel inserts for both sides of the steel frame. All electrical connections must be made<br />

by an electrical contractor. THIS TYPICAL INCLUDES:<br />

2 steel frames, 54"H (1372mm) x 36"W (914mm);<br />

3 steel frames, 38"H (965mm) x 24"W (610mm);<br />

1 steel frame w/low access, 38"H (965mm) x 48"W (1219mm);<br />

2 frame connectors, 3-way corner, 54"H (1372mm);<br />

4 finished end hardware;<br />

1 cantilevered work surface, 24"W (1219mm);<br />

1 cantilevered, low access work surface, 48"W (1219mm);<br />

1 pedestal, box/box/file;<br />

2 laminate panel inserts, 20"H (508mm) x 48"W (1219mm);<br />

1 panel insert, paper mgmt. 16"H (406mm) x 24"W (610mm);<br />

11 panel inserts, painted metal, 16"H (406mm) x 24"W (610mm);<br />

12 panel inserts, painted metal, 16"H (406mm) x 36"W (914mm);<br />

1 diagonal tray;<br />

2 paper trays.<br />

C<br />

C<br />

C<br />

V<br />

Amps1 15<br />

Amps2<br />

Weight (lbs) 225 Weight (kgs) 103<br />

Height (in) 65 Height (cen) 165<br />

Width (in) 79 Width (cen) 201<br />

Depth (in) 60 Depth (cen) 152<br />

Volts2<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour<br />

Watts1 1800<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 306 of 1462<br />

Watts2