JSN L0160<br />

Name Tissue Processor, Vacuum<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6600<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 12<br />

Amps2 0<br />

Weight (lbs) 353 Weight (kgs) 161<br />

Height (in) 54 Height (cen) 137<br />

Width (in) 24 Width (cen) 61<br />

Depth (in) 27 Depth (cen) 69<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 1440<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Vacuum infiltrator tissue processor. <strong>The</strong> unit is computer controlled and has a self-contained cleaning system. A pressure/vacuum cycle is<br />

provided for better infiltration and exchange of fluids. Used for specimen preparation for electron microscopes.<br />

JSN L0200<br />

Name Protein Analysis System<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Protein analysis system for use in the clinical laboratory. System includes the analyzer, a keyboard and CRT, and a printer for logging out<br />

the results of analysis.<br />

P<br />

Amps1 12<br />

Amps2 0<br />

Weight (lbs) 270 Weight (kgs) 123<br />

Height (in) 30 Height (cen) 76<br />

Width (in) 44 Width (cen) 112<br />

Depth (in) 26 Depth (cen) 66<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 2900<br />

Watts1 1440<br />

Watts2 0<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />