JSN M4871<br />

Name System, Reverse Osmosis, Water<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 4100<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 208<br />

Utility2: Electrical D | 120 and 208/220 volt<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 3<br />

Phase2 1<br />

Amps1 15<br />

Amps2 15<br />

Weight (lbs) 750 Weight (kgs) 341<br />

Height (in) 76 Height (cen) 193<br />

Width (in) 32 Width (cen) 81<br />

Depth (in) 42 Depth (cen) 107<br />

Volts2 120<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 5404<br />

Watts2 1800<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Reverse osmosis system to purify water in hemodialysis clinics and other clinical areas. <strong>The</strong> system consists of a pump, water softener,<br />

media and carbon filters, processing unit, ultraviolet sterilizer, final filtration, deionizers, osmosis units, controls and monitors. <strong>The</strong> system<br />

alarms when a malfunction occurs. <strong>The</strong> system usually requires a room of its own. Refer to the manufacturers specifications for exact<br />

installation requirements. Database system weight does not include the water in the piping or holding tanks of an operating system.<br />