JSN X4890<br />

Name Rad/Fluoro Unit, Digital, Mobile, C-Arm<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 25<br />

Amps2 0<br />

Weight (lbs) 650 Weight (kgs) 296<br />

Height (in) 77 Height (cen) 196<br />

Width (in) 85 Width (cen) 216<br />

Depth (in) 34 Depth (cen) 86<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 3000<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

This system is a high quality radiographic/fluoroscopic mobile digital C-arm for use in orthopedics, general surgery, urology, vascular,<br />

neurosurgery, neurovascular and cardiovascular procedures. This units characteristics and components include a high frequency x-ray<br />

generator with single or dual focus x-ray tube unit, 9” or 12” multi-field image intensifier, dual 16” monitors, real time digital imaging and<br />

last image hold capabilities. <strong>The</strong> system shall be DICOM 3.0 or latest version, compatible, for easy linkage to filmless image management<br />

systems and review stations.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />