JSN D0904<br />

Name Workstation, Tech, Dental, Lab, Single Station<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas D | Air, high pressure (85 PSIG) max<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas A | Natural gas<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 339 Weight (kgs) 154<br />

Height (in) 78 Height (cen) 198<br />

Width (in) 46 Width (cen) 117<br />

Depth (in) 24 Depth (cen) 61<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 4500<br />

Watts1 2400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Modular technician's workstation for the dental laboratory. <strong>The</strong> workstation features integrated gas, air, and electrical lines which all<br />

connect to building supplies from a single utility panel. <strong>The</strong> unit contains an overhead task lighting ( approx. 3000 Lux) array. <strong>The</strong><br />

workstation also includes a dust extraction system with filtration, a minimum of 4 drawers for storage, an air gun, a gas valve for a Bunsen<br />

burner and electrical outlets for accessory equipment. <strong>The</strong> desktop is made from a fiber/cement mixture or similar material to resist heat,<br />

abrasion, and chemical attack. This unit has a standard length work surface that varies among manufacturers but is nominally 43".<br />

Depending on the manufacturer, workstation package configurations may include seating and other minor accessories. <strong>The</strong> workstation<br />

may require more than one electrical connection to the facility power grid to run the equipment used on the bench. See JSN D0975 for an<br />

extended length workstation.<br />