05.04.2013 Views

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JSN L8000<br />

Name Incubator, Anaerobic, Vacuum<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas B | Vacuum<br />

Utility4: Misc Gas E | Carbon dioxide gas<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 15<br />

Amps2 0<br />

Weight (lbs) 290 Weight (kgs) 132<br />

Height (in) 30 Height (cen) 76<br />

Width (in) 61 Width (cen) 155<br />

Depth (in) 31 Depth (cen) 79<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1800<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Anaerobic incubator with vacuum. Unit has fluorescent lights, two adjustable shelves, reusable wafers and a 4 cubic foot capacity. Used<br />

for culture growth of anaerobic bacteria. Includes vacuum pump.<br />

JSN L8005<br />

Name Incubator, Blood Bank, Tabletop<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 2<br />

Weight (lbs) 9 Weight (kgs) 4<br />

Height (in) 4 Height (cen) 10<br />

Width (in) 10 Width (cen) 25<br />

Depth (in) 15 Depth (cen) 38<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch -1<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

<strong>The</strong> incubator is used to perform crossmatches, indirect Coombs test, Rh titers, Du tests. It maintains through the use of dry heat blocks a<br />

constant temperature of 37degrees centigrade with an accuracy within + or - .5 degrees centigrade. It accommodates up to 40 tubes with<br />

diameters of 12mm. It is designed to be placed on a table top and is approximately 5" x 9" x 3".<br />

Amps2<br />

BTU / Hour<br />

Watts1 150<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 802 of 1462<br />

Watts2