JSN L1780<br />

Name Centrifuge, Cytology<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 32 Weight (kgs) 15<br />

Height (in) 10 Height (cen) 25<br />

Width (in) 17 Width (cen) 43<br />

Depth (in) 25 Depth (cen) 64<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 600<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Cyto-Centrifuge. <strong>The</strong> characteristics/components include a specimen chamber designed to avoid slide damage, fluid path for premature<br />

absorption and a disinfectant tank for prevention of pathogenic aerosol. <strong>The</strong> unit has a maximum speed of approximately 2,000 RPM.<br />

Used for cell sedimentation and dispersion on a glass slide and other laboratory applications.<br />

JSN L1930<br />

Name Analyzer, pH/Blood Gas<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6630<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 10<br />

Amps2 0<br />

Weight (lbs) 73 Weight (kgs) 34<br />

Height (in) 22 Height (cen) 56<br />

Width (in) 28 Width (cen) 71<br />

Depth (in) 23 Depth (cen) 58<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1200<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

PH/blood gas analyzer. <strong>The</strong> unit measures pH, PCO2 and P02 and performs calculations for CO2, HCO3, and base excess. Characteristics<br />

of the unit include: an automatic calibration capability and measurement ranges of 6.4 to 8.0 for pH; 0 to 800 mmHg for PO2; and 8.0 to<br />

200.mmHg. for PCO2. Used in laboratories to conduct pH/blood gas determinations.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />