JSN K1720<br />

Name Counter, Cafeteria, Utility, W/Power 36x50x40<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 7310<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 15<br />

Amps2 0<br />

Weight (lbs) 314 Weight (kgs) 143<br />

Height (in) 36 Height (cen) 91<br />

Width (in) 50 Width (cen) 127<br />

Depth (in) 39 Depth (cen) 99<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1800<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Food Service <strong>Equipment</strong><br />

Mobile cafeteria utility counter. <strong>The</strong> unit is made of stainless steel, can serve as a mobile utility table and has an open working side with<br />

bottom and intermediate shelves, a drop-type solid or three rail tray slide, four 5-inch swivel casters and 120V AC outlets. User must<br />

specify outlet requirements and configuration. Multiple facility-level outlets may be required depending on the number of convenience<br />

outlets the end user requires. <strong>The</strong> exact unit dimensions depend on the specific manufacturer; refer to the technical data sheets. <strong>The</strong><br />

database depth dimension does not include the fold down tray rail but does include the 8-10" working shelf on the server's side. This unit<br />

is used in commercial and hospital food service areas.<br />