JSN R2202<br />

Name Fountain, Water, CRS, Wall Mounted, Handicap<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 70 Weight (kgs) 32<br />

Height (in) 27 Height (cen) 69<br />

Width (in) 18 Width (cen) 46<br />

Depth (in) 19 Depth (cen) 48<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 600<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Refrigeration<br />

Drinking water fountain. This unit is semi-recessed and wall mounted at handicap level with an air cooled compressor. <strong>The</strong> unit provides<br />

easy access with push-bar/button. <strong>The</strong> unit provides cool drinking water in hospitals and commercial office buildings to include access by<br />

handicapped persons.<br />

JSN R2203<br />

Name Fountain, Water, CRS, Wall Mounted, Recessed<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 9<br />

Amps2 0<br />

Weight (lbs) 116 Weight (kgs) 53<br />

Height (in) 56 Height (cen) 142<br />

Width (in) 19 Width (cen) 48<br />

Depth (in) 16 Depth (cen) 41<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1080<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Refrigeration<br />

Drinking water fountain. Unit is fully-recessed and wall mounted, with an air-cooled compressor. Unit must be specified with or without<br />

glass filler. <strong>The</strong> unit provides easy access with push bars or button. <strong>The</strong> unit is used in hospitals and commercial office buildings.<br />