JSN K1730<br />

Name Counter, Cafeteria, Utility, W/Power 48x64x32<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 7310<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 380 Weight (kgs) 173<br />

Height (in) 48 Height (cen) 122<br />

Width (in) 64 Width (cen) 163<br />

Depth (in) 32 Depth (cen) 81<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Food Service <strong>Equipment</strong><br />

Mobile cafeteria utility counter. This is a stainless steel unit with a sneeze guard, a drop-type solid or three rail tray slide, intermediate and<br />

bottom shelves, four 5-inch swivel casters and two 120V AC outlets in the control panel below work shelf. <strong>The</strong> end user must specify<br />

outlet requirements and configuration. <strong>The</strong> database depth dimension does not include the tray slide. <strong>The</strong> database width and depth<br />

dimensions vary slightly according to manufacturer. <strong>The</strong> counter height is 36". Multiple facility level connections may be required for<br />

powering this unit. This unit is used in commercial and hospital service areas.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />