JSN A1105<br />

Name Headwall, Prefabricated, ICU, With <strong>Equipment</strong><br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas G | Oxygen, vacuum and medical air (50 PSIG)<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc A | Earth ground<br />

Phase1 1<br />

Phase2 0<br />

Amps1 15<br />

Amps2 0<br />

Weight (lbs) 600 Weight (kgs) 273<br />

Height (in) 107 Height (cen) 272<br />

Width (in) 122 Width (cen) 310<br />

Depth (in) 8 Depth (cen) 20<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1800<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Architectural<br />

ICU prefabricated headwall with equipment. Multi-wall surface mounted unit. Consists of: patient medical gases, and electrical module;<br />

and patient cabinet module. Includes examination lamp, elapsed time recorder, wall mounted sphygmomanometer, ceiling mounted<br />

intravenous arm assembly; Electro/safe hazard cardiac monitor shelf; vacuum bottle storage unit, medical gas/vacuum outlet and external<br />

grounding receptacles.<br />

JSN A1106<br />

Name Medical Gas Outlet Location - In OR Wall<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas G | Oxygen, vacuum and medical air (50 PSIG)<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc A | Earth ground<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 0 Weight (kgs) 0<br />

Height (in) 0 Height (cen) 0<br />

Width (in) 0 Width (cen) 0<br />

Depth (in) 0 Depth (cen) 0<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Description<br />

Unit of Issue LT<br />

Group Architectural<br />

Medical gas outlet location, installed within the finished wall, as defined by the architect. Operating room configuration.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />