JSN R8000<br />

Name Refrigerator, Morgue, 4 Cadaver<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing I | Drain only<br />

Volts1 208<br />

Utility2: Electrical C | 208/220 volt<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc C | Remote alarm ground<br />

Phase1 1<br />

Phase2 0<br />

Amps1 15<br />

Amps2 0<br />

Weight (lbs) 2710 Weight (kgs) 1231<br />

Height (in) 81 Height (cen) 206<br />

Width (in) 73 Width (cen) 185<br />

Depth (in) 96 Depth (cen) 243<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 7020<br />

Watts1 3120<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Refrigeration<br />

Mortuary refrigerator approximately 73" W x 96' D x 76' H. This unit accommodates four cadavers. <strong>The</strong> unit is used in hospital morgues<br />

and funeral homes for refrigerated cadaver storage.<br />

JSN R8200<br />

Name Refrigerated Room, Mortuary, 3 Cart<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 208<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 3<br />

Phase2 1<br />

Amps1 12<br />

Amps2 1<br />

Weight (lbs) 2243 Weight (kgs) 1019<br />

Height (in) 103 Height (cen) 262<br />

Width (in) 129 Width (cen) 328<br />

Depth (in) 152 Depth (cen) 386<br />

Volts2 115<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 7175<br />

Watts1 4323<br />

Watts2 115<br />

Description<br />

Unit of Issue EA<br />

Group Refrigeration<br />

Mortuary refrigerated room accommodates 3 cadaver carts. <strong>The</strong> unit is used in hospital morgues and funeral homes to store cadavers<br />

under refrigeration where the cadaver cart is also the autopsy table. Custom built to meet site requirements.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 1199 of 1462