JSN D4500<br />

Name Furnace, Laboratory, Dental, Burnout<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6520012558162<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 12<br />

Amps2 0<br />

Weight (lbs) 59 Weight (kgs) 27<br />

Height (in) 21 Height (cen) 53<br />

Width (in) 15 Width (cen) 38<br />

Depth (in) 16 Depth (cen) 41<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Dental burnout furnace. <strong>The</strong> unit is used in dental laboratories for burnout of dental alloy rings and flasks. <strong>The</strong> furnace is capable of<br />

automatic or manual operation and has a automatic self-calibration system as well as a digital readout. <strong>The</strong> unit can hold a minimum of<br />

fifteen 1-3/4" inlay rings. Some model lines are available with several sizes of heating elements and/or for other power configurations.<br />

JSN D4510<br />

Name Furnace, Laboratory, Porcelain Glazing<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 7 Weight (kgs) 4<br />

Height (in) 12 Height (cen) 30<br />

Width (in) 8 Width (cen) 20<br />

Depth (in) 7 Depth (cen) 18<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 840<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Dental laboratory furnace. <strong>The</strong> furnace is used for porcelain glazing and staining and is equipped with an automatic pyrometer and an<br />

alarm.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 210 of 1462