JSN V0007<br />

Name Cage, Transport, Aluminum, Large<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 450 Weight (kgs) 205<br />

Height (in) 51 Height (cen) 130<br />

Width (in) 29 Width (cen) 74<br />

Depth (in) 87 Depth (cen) 221<br />

Volts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Veterinary<br />

Cage, transfer, aluminum, for large animals. Approximate dimensions: 28 1/2 W x 87 L x 51 H. Constructed of series 6000 aluminum alloy<br />

and other non-corrosive materials. Guillotine doors on either end, individually removable bars, and squeeze back.<br />

JSN V0008<br />

Hertz<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Name Rack, 4 Each, Single Cage, Primate<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 350 Weight (kgs) 159<br />

Height (in) 83 Height (cen) 211<br />

Width (in) 59 Width (cen) 150<br />

Depth (in) 35 Depth (cen) 89<br />

Volts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Veterinary<br />

Rack, single cage, primate, 2 tiers, holds 2 cages per tier. Approximate cage dimensions: 24" W x 28" D x 34" H. Stainless steel excreta<br />

tray and horizontal water supply line are included. Other accessories such as feeders and water bottles are ordered separately.<br />

Hertz<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />