05.04.2013 Views

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

JSN M0820<br />

Name Warmer, Infant, Mobile<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 7<br />

Amps2 0<br />

Weight (lbs) 260 Weight (kgs) 118<br />

Height (in) 86 Height (cen) 218<br />

Width (in) 30 Width (cen) 76<br />

Depth (in) 47 Depth (cen) 119<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 840<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Unit includes a clear plastic bassinet, heat source and a temperature monitor/timer.<br />

JSN M0825<br />

Name Transilluminator, Neonatal<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6515<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 2<br />

Amps2 0<br />

Weight (lbs) 10 Weight (kgs) 5<br />

Height (in) 8 Height (cen) 20<br />

Width (in) 16 Width (cen) 41<br />

Depth (in) 11 Depth (cen) 28<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 240<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Fiberoptic transilluminator for use in newborn and neonatal intensive care nurseries. <strong>The</strong> source and fiberoptic bundle provide a variable<br />

intensity light for transillumination of infant body structures. Red or white light models available. Some models are handheld and have<br />

recharging stands; others have mounted power sources and long flexible arms. Database physical dimensions are for either the handheld<br />

unit or the fixed mount power source. <strong>The</strong> unit is used primarily to locate venipuncture sites and diagnose pneumothorax, intercranial<br />

hemorrhaging, hydrocephalus or other physiologic problems.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 855 of 1462

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!