JSN X2110<br />

Name Scanner, Ultrasound, Pulsed Doppler<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6515<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 500 Weight (kgs) 227<br />

Height (in) 64 Height (cen) 163<br />

Width (in) 26 Width (cen) 66<br />

Depth (in) 42 Depth (cen) 107<br />

Volts2 0<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 4100<br />

Watts1 2400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

High definition, diagnostic ultrasound system for Radiology, Cardiology, Vascular, ob-gyn, Perinatology, and Surgical imaging<br />

applications. <strong>The</strong> unit employs curved, phased and linear array imaging technology. <strong>The</strong> system supports colorflow, pulse, and<br />

continuous wave, imaging modalities. On board software measurement packages available for all imaging applications. <strong>The</strong> system is<br />

DICOM 3.0 compatible, for easy linkage to filmless image management systems and review stations. In addition, a full line of probes and<br />

conventional recording devices are available.<br />