JSN L1130<br />

Name Densitometer, Scanning<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 4<br />

Amps2 0<br />

Weight (lbs) 104 Weight (kgs) 48<br />

Height (in) 22 Height (cen) 56<br />

Width (in) 45 Width (cen) 114<br />

Depth (in) 24 Depth (cen) 61<br />

Volts2 0<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 480<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Scanning densitometer. This is a high capacity, fully automated unit. <strong>The</strong> unit can accommodate routine media, agarose film, cellulose<br />

acetate, TLC plates and fluorescence wavelengths. <strong>The</strong> carrier can accept media up to 150mm and run up to four tests and analyze 64<br />

scans in 12 minutes. Used for electrophoresis scanning. System includes computer and printer.<br />

JSN L1160<br />

Name Densitometer, Blood<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 4<br />

Amps2 0<br />

Weight (lbs) 104 Weight (kgs) 48<br />

Height (in) 22 Height (cen) 56<br />

Width (in) 18 Width (cen) 46<br />

Depth (in) 24 Depth (cen) 61<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 480<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Blood densitometer. <strong>The</strong> characteristics include automatic computer capabilities, automatic calibration and scanning. <strong>The</strong> densitometer<br />

has a fluorescence lamp, two detectors, shall scan all standard media at a rate of 1 per 6 seconds and have a capacity of up to 30 fractions<br />

per sample. It can be used to handle both colorimetric and fluorometric procedures. Includes PC computer and printer.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />