JSN P3071<br />

Name Lavatory, Vitreous China, Under counter<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 25 Weight (kgs) 12<br />

Height (in) 7 Height (cen) 18<br />

Width (in) 20 Width (cen) 51<br />

Depth (in) 16 Depth (cen) 41<br />

Description<br />

Unit of Issue EA<br />

Group Plumbing Fixtures<br />

An undercounter mounted vitreous china lavatory (bowl size approximately 16" W x 13" D x 6"H) with faucet and grid drain.<br />

Undercounter lavatory will have unglazed rim with mounting kit provided. For general use in public, patient and staff bathrooms.<br />

JSN P3100<br />

NSN<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1<br />

Watts2<br />

Name Lavatory, Vitreous China, Slab Type<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4510<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 52 Weight (kgs) 24<br />

Height (in) 21 Height (cen) 53<br />

Width (in) 20 Width (cen) 51<br />

Depth (in) 19 Depth (cen) 48<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Plumbing Fixtures<br />

Wall mounted, slab type, vitreous china, lavatory (approximate bowl size 7"x15"x10") with: faucet holes on 4" centers; gooseneck spout;<br />

wrist blade handles; and grid strainer. It shall be suitable for use in clinics, offices, washrooms or patient care area.<br />