JSN M1801<br />

Name Computer, Microprocessing, w/Flat Panel Monitor<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 7025<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 5<br />

Weight (lbs) 45 Weight (kgs) 21<br />

Height (in) 23 Height (cen) 58<br />

Width (in) 24 Width (cen) 61<br />

Depth (in) 19 Depth (cen) 48<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Desk top microprocessing computer. <strong>The</strong> unit shall consist of a central processing mini tower, flat panel monitor, keyboard, mouse and<br />

speakers. <strong>The</strong> system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MB memory; 80GB hard drive;<br />

32/48x CD-ROMDVD combo; 1.44MB network interface card; video 32 MB NVIDIA; a 18 inch flat panel monitor. <strong>The</strong> computer is used<br />

throughout the facility to input, manipulate and retrieve information.<br />

JSN M1802<br />

Amps2<br />

BTU / Hour<br />

Watts1 600<br />

Watts2<br />

Name Work Station, Computer, Retractable, Wall Mounted<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 7110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc D | Empty conduit with pull cord<br />

Phase1 1<br />

Phase2 0<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 58 Weight (kgs) 27<br />

Height (in) 28 Height (cen) 71<br />

Width (in) 32 Width (cen) 81<br />

Depth (in) 6 Depth (cen) 15<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 600<br />

Watts2<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

A wall mounted retractable work station. Work station is used as a computer station in treatment rooms, exam rooms and areas where<br />

physical space in limited.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 872 of 1462