JSN X8501<br />

Name Simulator, <strong>The</strong>rapy, X-Ray<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 480<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc B | Lead lined walls<br />

Phase1 3<br />

Phase2 1<br />

Amps1 120<br />

Amps2 50<br />

Weight (lbs) 11326 Weight (kgs) 5142<br />

Height (in) 0 Height (cen) 0<br />

Width (in) 0 Width (cen) 0<br />

Depth (in) 0 Depth (cen) 0<br />

Volts2 120<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 14336<br />

Watts1 99764<br />

Watts2 6000<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

This system is specifically designed to simulate radiotherapy treatment plans in the Oncology Department. <strong>The</strong> characteristics and<br />

components include a precise mechanical system including digital fluoroscopic and radiographic x-ray capabilities and a flexible computer<br />

system. It shall have the capability to simulate any linear accelerator. Shall include a couch, collimator and accessories. Movements and<br />

scales shall be a match to other treatment machines to maintain their integrity of simulation for all cancer treatments. <strong>The</strong> system shall be<br />

DICOM RT compatible, for easy linkage to film-less image management systems and review stations.<br />