JSN X4112<br />

Name Console, PACS, Remote View, 1k X 1k, 2 Monitors<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 9<br />

Amps2 0<br />

Weight (lbs) 350 Weight (kgs) 159<br />

Height (in) 29 Height (cen) 74<br />

Width (in) 48 Width (cen) 122<br />

Depth (in) 29 Depth (cen) 74<br />

Volts2 0<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1080<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Two monitor remote viewing station for picture archiving and retrieval (PACS) system. This station is for use by providers inside or outside<br />

of radiology to review images. Station includes local image storage, image manipulation, and simultaneous display of multiple images on<br />

two 1024 x 1024 image display monitors. Images are stored on a resident hard disk and roll off the disk as more recent images are sent to<br />

the station. Provider may request images from the PACS. Unit must be connected to the PACS by LAN for image and result receipt. This<br />

station is for use in areas like radiologist's offices and the E.R. where a more comprehensive system is required. Console must be DICOM<br />

compliant. Input may be by keyboard, mouse, trackball or voice activated commands.<br />