JSN C04K0<br />

Name Cabinet, U/C/B, 1 Shelf, 6 Half DR, 1 DO, 36x36x22<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 170 Weight (kgs) 78<br />

Height (in) 36 Height (cen) 91<br />

Width (in) 36 Width (cen) 91<br />

Depth (in) 22 Depth (cen) 55<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Fixed Casework<br />

Standing height under counter base cabinet with one adjustable shelf, two shallow half width drawers above a solid right or left<br />

door/cupboard (appropriate door/cupboard configuration to be indicated on equipment elevation drawings), and four half width drawers<br />

alongside. Also referred to as a combination cabinet or drawer and cupboard cabinet. For general purpose use throughout the facility.<br />

JSN C04L0<br />

Name Cabinet, U/C/B, 1 DR, 3 Half DR, 1 Door, 36" W<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 155 Weight (kgs) 71<br />

Height (in) 36 Height (cen) 91<br />

Width (in) 36 Width (cen) 91<br />

Depth (in) 22 Depth (cen) 55<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Fixed Casework<br />

Standing height under counter base cabinet, 36" H x 36" W x 22" D with a full width drawer above three half width drawers alongside a<br />

solid right or left door/cupboard (appropriate door/cupboard configuration to be indicated on equipment elevation drawings). Also<br />

referred to as a combination cabinet or a drawer and cupboard cabinet. For general purpose use throughout the facility.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />