JSN X5445<br />

Name Table, Breast Biopsy<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 2<br />

Amps2 0<br />

Weight (lbs) 315 Weight (kgs) 143<br />

Height (in) 38 Height (cen) 97<br />

Width (in) 27 Width (cen) 69<br />

Depth (in) 72 Depth (cen) 183<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 240<br />

Watts2<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Decubitus breast imaging table used in performing core breast biopsies. Table provides 360 degree access to the breast. Table is used<br />

for stereotaatic breast biopsy procedures, as well as for stretcher mammography, ultrasound guided biopsy, needle location and can be<br />

used as a flat exam table.<br />

JSN X5500<br />

Name Radiographic Unit, Cephalometric<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc B | Lead lined walls<br />

Phase1 1<br />

Phase2 1<br />

Amps1 10<br />

Amps2 12<br />

Weight (lbs) 568 Weight (kgs) 258<br />

Height (in) 93 Height (cen) 236<br />

Width (in) 79 Width (cen) 201<br />

Depth (in) 54 Depth (cen) 137<br />

Volts2 230<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 1200<br />

Watts2 2760<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Cephalometric radiographic unit. This unit shall have electronic timing with automatic reset timing capability and a main correction unit to<br />

adjust for line voltage fluctuations. Tube head shall be of the oil immersed shield-type with a total inherent filtration of 3.3 mm A1 and a<br />

focal spot of 0.9.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />