JSN M8556<br />

Name Electrosurgical Unit, Endoscopy<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6515<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 9<br />

Amps2 0<br />

Weight (lbs) 31 Weight (kgs) 14<br />

Height (in) 7 Height (cen) 18<br />

Width (in) 16 Width (cen) 41<br />

Depth (in) 15 Depth (cen) 38<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch -1<br />

BTU / Hour<br />

Watts1 1080<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Electrosurgical unit for endoscopy procedures. Unit is designed for tissue cutting, coagulation, polyp removal and general surgical<br />

procedures. Unit produces varying radio frequency electric current waveforms (cut, blended, coagulation), for different treatment<br />

procedures. Unit can support monopolar and bipolar electrosurgical instruments and includes a safety system which shuts off current if<br />

leads or cables are improperly connected. This unit is also a component of the M8605-M8607 and M8610-M8611 endoscopy carts.<br />

JSN M8557<br />

Name Suction Unit, Endoscopy<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6515<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 1<br />

Amps2 0<br />

Weight (lbs) 15 Weight (kgs) 7<br />

Height (in) 15 Height (cen) 38<br />

Width (in) 12 Width (cen) 30<br />

Depth (in) 16 Depth (cen) 41<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour<br />

Watts1 120<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Suction unit for endoscopy procedures. Unit works with a wide variety of fiberoptic and video endoscopes. This unit is also a component<br />

of the JSN M8605-M8607 and M8610-M8611 endoscopy carts.<br />