JSN M0720<br />

Name Analyzer, Pulmonary Function, w/Computer<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6516<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas F | Oxygen and medical air (50 PSIG)<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc F | Special gas requirements<br />

Phase1 1<br />

Phase2 0<br />

Amps1 5<br />

Amps2 0<br />

Weight (lbs) 400 Weight (kgs) 182<br />

Height (in) 78 Height (cen) 198<br />

Width (in) 62 Width (cen) 157<br />

Depth (in) 62 Depth (cen) 157<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 600<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Pulmonary function analyzer system. Unit includes whole body plethysmography, spirometer, computer, and gas analyzers. Computer<br />

based system for use in cardio-pulmonary areas. <strong>The</strong> system measures the ventilation, diffusion and distribution of gases in the lungs. It<br />

has automatic calibration and valves are pneumatically operated and controlled by the computer. Used to measure the performance of a<br />

patient's respiratory system; for out-patient or pre-surgical screening. Systems have specific high pressure air and oxygen and low<br />

pressure helium requirements. Refer to manufacturer's literature.<br />