JSN T8000<br />

Name Machine, Sewing/Stitching<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 3530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 10<br />

Amps2 0<br />

Weight (lbs) 210 Weight (kgs) 96<br />

Height (in) 48 Height (cen) 122<br />

Width (in) 30 Width (cen) 76<br />

Depth (in) 17 Depth (cen) 43<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1200<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Shop <strong>Equipment</strong>/Tools<br />

Industrial type sewing machine. Single needle, extra heavy duty backstitch with reverse feed. Has an extra long cylinder arm and built in<br />

bobbin winder. Also has an extra high presser lift for sewing very heavy materials. This machine is used for sewing leather, canvas, nylon<br />

and other heavy materials.<br />

JSN T8005<br />

Name Signal - Differential Amp. Analyzer<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6625<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 3<br />

Amps2 0<br />

Weight (lbs) 46 Weight (kgs) 21<br />

Height (in) 9 Height (cen) 24<br />

Width (in) 17 Width (cen) 43<br />

Depth (in) 22 Depth (cen) 56<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 360<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Shop <strong>Equipment</strong>/Tools<br />

Signal analyzer. This unit is capable of analyzing the electrical signals for distortion, networking, noise levels, and burst signals. <strong>The</strong><br />

system can be used to determine Electro magnetic interface and many other applications. <strong>The</strong> unit is programmable to measure and<br />

analyze all aspects of signal transmission. Used in research and maintenance in a healthcare facility.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />