JSN X6400<br />

Name Rad/Fluoro Unit, 80 kW, 15" I.I., 90/90 Table, DIG<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 400<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc B | Lead lined walls<br />

Phase1 3<br />

Phase2 3<br />

Amps1 142<br />

Amps2 117<br />

Weight (lbs) 6855 Weight (kgs) 3113<br />

Height (in) 0 Height (cen) 0<br />

Width (in) 0 Width (cen) 0<br />

Depth (in) 0 Depth (cen) 0<br />

Volts2 480<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch -1<br />

BTU / Hour 12564<br />

Watts1 98378<br />

Watts2 97270<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

This system is specifically designed to perform radiographic/fluoroscopic examinations in the Radiology Department. On-line digital<br />

image processing will provide instant availability of images for review. <strong>The</strong> characteristics and components include a ceiling suspended<br />

0.6/1.0 mm tube unit, 80 kW micro-processor controlled X-ray generator, 90/90 table with 15” multi-field Image Intensifier (I.I.). <strong>The</strong><br />

system shall be DICOM 3.0 compatible, for easy linkage to filmless image management systems and review stations. It is recommended<br />

that the TV monitors be ceiling suspended.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />