JSN X9900<br />

Name MRI System, Open<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing J | Cold water only<br />

Volts1 480<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 3<br />

Phase2 1<br />

Amps1 125<br />

Amps2 79<br />

Weight (lbs) 35300 Weight (kgs) ####<br />

Height (in) 107 Height (cen) 272<br />

Width (in) 124 Width (cen) 315<br />

Depth (in) 176 Depth (cen) 447<br />

Volts2 240<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch -1<br />

BTU / Hour 38251<br />

Watts1 103920<br />

Watts2 18960<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Open Magnetic Resonance Imaging (MRI) System that uses magnetic fields in the range of 0.2 to 0.5 tesla and radio-frequency (RF)<br />

radiation to translate hydrogen nuclei distribution in body tissues into computer-generated images of anatomic structures. MRI is<br />

primarily used to identify diseases of the central nervous system, brain, and spine and to detect musculoskeletal disorders. System<br />

includes DICOM 3.0 or latest version software protocol. System to be procured with turnkey installation.<br />