JSN X3940<br />

Name Illuminator, Film, 8 Panels, Wall Mounted<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 8<br />

Amps2 0<br />

Weight (lbs) 184 Weight (kgs) 84<br />

Height (in) 44 Height (cen) 112<br />

Width (in) 59 Width (cen) 150<br />

Depth (in) 6 Depth (cen) 15<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 960<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Film illuminator, 8 panels, wall mounted. This unit has a stainless steel or light gray baked enamel finish. It consists of two 4-panel<br />

illuminators, with dual switches and torque grip film holders. <strong>The</strong> lower illuminator is tilted 35 degrees from the vertical while the upper<br />

illuminator is vertical (on two tier unit). It is arranged to facilitate handling of the films and especially effective for seated viewing. <strong>The</strong><br />

unit is used to review and analyze X-ray films.<br />