JSN A1125<br />

Name Headwall, Suspended System<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas G | Oxygen, vacuum and medical air (50 PSIG)<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc J | Wall/ceiling support required<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 1275 Weight (kgs) 579<br />

Height (in) Height (cen)<br />

Width (in) Width (cen)<br />

Depth (in) Depth (cen)<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2400<br />

Watts2<br />

Description<br />

Unit of Issue EA<br />

Group Architectural<br />

A wall mounted articulating boom system that provides the flexibility of a ceiling boom and the practicality of a headwall. Unit has an arm<br />

range of 190 degrees and 330 degree head rotation. Provides availability of retractable or fixed, single or double arms. Unit can supply<br />

up to 16 gas outlets and up to 40 line voltage receptacles and 12 low voltage provisions. Unit provides multiple bed/caregiver interface<br />