JSN X1415<br />

Name Laser Positioning System, Patient-Wall<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 115<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 1<br />

Amps2 0<br />

Weight (lbs) 15 Weight (kgs) 7<br />

Height (in) 18 Height (cen) 46<br />

Width (in) 6 Width (cen) 15<br />

Depth (in) 4 Depth (cen) 10<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 115<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Laser positioning system. This unit is designed for accurate patient alignment for radiation therapy. Three vertical laser beams and a<br />

horizontal beam intersect to define the iso-center to aid in patient positioning. <strong>The</strong> unit is generally supplied as a component of various<br />

radiation therapy systems.<br />

JSN X1416<br />

Name Laser Positioning System, Patient-Ceiling<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army F | Government Furnished, Government Installed<br />

Navy F | Government Furnished, Government Installed<br />

USAF F | Government Furnished, Government Installed<br />

VA F | Government Furnished, Government Installed<br />

IHS F | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6525<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 1<br />

Amps2 0<br />

Weight (lbs) 15 Weight (kgs) 7<br />

Height (in) 17 Height (cen) 43<br />

Width (in) 6 Width (cen) 15<br />

Depth (in) 4 Depth (cen) 10<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 120<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group X-Ray <strong>Equipment</strong> and Accessories<br />

Laser positioning system. This unit is designed for accurate patient alignment for radiation therapy. Three vertical laser beams and a<br />

horizontal beam intersect to define the iso-center to aid in patient positioning. <strong>The</strong> unit is generally supplied as a component of various<br />

radiation therapy systems.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 1333 of 1462

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!