05.04.2013 Views

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JSN L2540<br />

Name Incubator, Co2, 2 Chamber<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 8<br />

Amps2 0<br />

Weight (lbs) 530 Weight (kgs) 241<br />

Height (in) 79 Height (cen) 201<br />

Width (in) 34 Width (cen) 86<br />

Depth (in) 25 Depth (cen) 64<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 960<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Dual chamber Co2 incubator. <strong>The</strong> unit includes a temperature range of from 5 above ambient to 60 degrees centigrade, stainless steel<br />

construction, adjustable shelves, inner glass doors, 10 to 12 cubic foot capacity and a temperature safety controller. This is a fully<br />

automatic unit. It is used in laboratories to grow anaerobic bacterial cultures.<br />

JSN L2550<br />

Name Incubator, Bacteriological<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640004288620<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 7<br />

Amps2 0<br />

Weight (lbs) 325 Weight (kgs) 148<br />

Height (in) 39 Height (cen) 99<br />

Width (in) 42 Width (cen) 107<br />

Depth (in) 27 Depth (cen) 69<br />

Volts2 0<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 840<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Bacteriological incubator with a capacity of 10.5 cubic feet and approximately 34"W x37"H x 25"D. <strong>The</strong> unit comes with a thermostat and<br />

LED display, corrosion resistant interior with chrome plated shelves, fiberglass insulation in the shell, tempered glass inner door, a<br />

temperature range of 35-65 degrees centigrade and a forced air circulation system. Used in laboratories to grow cultures.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />