JSN A1107<br />

Name Rail System , Utility, Gas and Electric<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas G | Oxygen, vacuum and medical air (50 PSIG)<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc A | Earth ground<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 0 Weight (kgs) 0<br />

Height (in) 96 Height (cen) 244<br />

Width (in) 120 Width (cen) 305<br />

Depth (in) 10 Depth (cen) 25<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Architectural<br />

<strong>The</strong> headwall rail system shall consist of three horizontal rails mounted to the patient room headwall to provide utilities and patient<br />

services to support ancillary equipment to include gas and vacuum. <strong>The</strong> rail system must be capable of quickly adding or relocating<br />

medical gases services and be able to accept new equipment, provide physical support to equipment, brackets, shelves and other patient<br />

support items.<br />