JSN R8215<br />

Name Refrigerated Room, Mortuary, 6 Cart<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing I | Drain only<br />

Volts1 208<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc C | Remote alarm ground<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 4668 Weight (kgs) 2120<br />

Height (in) 103 Height (cen) 262<br />

Width (in) 162 Width (cen) 411<br />

Depth (in) 192 Depth (cen) 488<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 4160<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Refrigeration<br />

Mortuary refrigerated room accommodates 6 cadaver carts. <strong>The</strong> unit is used in hospital morgues and funeral homes to store cadavers<br />

under refrigeration where the cadaver cart is also the autopsy table. Custom built to meet site requirements.<br />

JSN R8400<br />

Name Refrigerator, Passthru, 50 Cubic Feet<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 4110<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 16<br />

Amps2 0<br />

Weight (lbs) 750 Weight (kgs) 341<br />

Height (in) 84 Height (cen) 213<br />

Width (in) 59 Width (cen) 150<br />

Depth (in) 40 Depth (cen) 102<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 3637<br />

Watts1 1920<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Refrigeration<br />

Pass through refrigerator, approximately 50 cubic feet and 84" H x 53" W x 40" D. This unit has 2 sections with a pass through feature. All<br />

components of the self-contained refrigeration system are mounted on top of the cabinet and concealed behind a louvered grill. This unit<br />

is used in large kitchens of hotels, restaurants and hospitals for food storage.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />

Page 1201 of 1462

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!