JSN L2310<br />

Name Cabinet, Bio Safety, Class II/A1, F/S, Vert, 4ft<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 20<br />

Amps2 0<br />

Weight (lbs) 730 Weight (kgs) 332<br />

Height (in) 98 Height (cen) 249<br />

Width (in) 54 Width (cen) 137<br />

Depth (in) 32 Depth (cen) 81<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2400<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Bio safety cabinet, Class II, Type A1. This is a vertical freestanding unit with a face velocity of 100 fpm, constructed of type 304 stainless<br />

steel. <strong>The</strong> inside walls have a high velocity air return. <strong>The</strong> unit utilizes 70% air recirculation 30% exhaust either into room or through to<br />

the outside. It requires HEPA and includes a removable work tray, built-in drain valve, two valve penetrations with blanking plugs, duplex<br />

outlet and a fluorescent lamp. Used for low to moderate risk biological agents with the absence of volatile toxic chemicals and<br />

radionuclides. 4 foot model, other sizes available.<br />