11.07.2015 Views

Fac-simile Scheda Linee di Ricerca - Federalimentare

Fac-simile Scheda Linee di Ricerca - Federalimentare

Fac-simile Scheda Linee di Ricerca - Federalimentare

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5. Badea M., Micheli L., Messia M.C., Can<strong>di</strong>gliota T., Marconi E., Mottram T., Velasco-GarciaM., Moscone D., Palleschi G. (2004). Aflatoxin M1 determination in raw milk using a flowinjectionimmunoassay system. Analytica Chimica Acta, 520, 141-148.A flow-injection immunoassay (FI-IA) method with amperometric detection for aflatoxin M1 (AFM1) determinationin milk has been developed. The first step consists in an incubation of the sample containing AFM1 (Ag)with fixed amounts of anti-AFM1 antibody (Ab) and of the tracer (Ag*, AFM1 covalently coupled to HRP) untilequilibrium is reached. In this mixture a competition occurs between Ag and Ag* for the Ab. The mixture is theninjected into a flow system where the separation of the free tracer (Ag*) and the antibody-bound tracer (AbAg*)is performed in a column with immobilized Protein G. The antigen–antibody complexes are retained in the columndue to the high affinity of the Protein G for the antibody. The activity of the eluted enzyme label is thenamperometrically detected. The immunoassay was optimised relative to con<strong>di</strong>tions for antibody–antigen incubation(pH, incubation time, ionic strength, temperature) and enzymatic label detection. This method showed a dynamicconcentration range between 20 and 500 ppt AFM1, a low detection limit (11 ppt), good reproducibility(RSD < 8%) and a high throughput (six samples per hour in triplicate). Different milk samples were analysedand the results were in good agreement with those obtained by HPLC using the AOAC 2000.08 method.6. Marconi E., Messia M.C., Palleschi G., Cubadda R. (2004). A maltose biosensor for determininggelatinized starch in processed cereal foods. Cereal Chemistry, 81, 6-9.A reliable method for the quantitative determination of gelatinized starch in processed cereal foods was developed.It consists of an electrochemical biosensor based on amyloglucosidase and glucose oxidase enzymes coimmobilizedon a Pt electrode surface, and a third enzyme, α-amylase, added in solution. Analytical parameterssuch as time, temperature, and enzyme units were optimized. The degree of starch gelatinization was determine<strong>di</strong>n <strong>di</strong>fferent processed cereal foods using the biosensor method and the results were commensurate to those obtainedwith the reference method. The biosensor method showed good accuracy (r 2 = 0.9629; relative error

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!