ESIB<br />

Screen<br />

FRQ<br />

SGL<br />

A frequency offset ≠ 0 Hz has been set.<br />

The scan/sweep is set to SINGLE SCAN or SINGLE SWEEP.<br />

1-<br />

2-<br />

3-<br />

4-<br />

AP<br />

MA<br />

MI<br />

SA<br />

AV<br />

RM<br />

QP<br />

AC<br />

GAT<br />

TRG<br />

EXT<br />

Subtraction Trace 1 - Trace active (: numeric value) or<br />

subtraction Trace 1 - Reference Line active (: R)<br />

Subtraction Trace 2 - Trace active (: numeric value) or<br />

subtraction Trace 1 - Reference Line active (: R)<br />

Subtraction Trace 3 - Trace active (: numeric value) or<br />

subtraction Trace 1 - Reference Line active (: R)<br />

Subtraction Trace 4 - Trace active (: numeric value) or<br />

subtraction Trace 1 - Reference Line active (: R)<br />

For trace (n = 1 to 4) the detector is set to AUTOPEAK.<br />

For trace (n = 1 to 4) the detector is set to MAX PEAK.<br />

For trace (n = 1 to 4) the detector is set to MIN PEAK.<br />

For trace (n = 1 to 4) the detector is set to SAMPLE.<br />

For trace (n = 1 to 4) the detector is set to AVERAGE.<br />

For trace (n = 1 to 4) the detector is set to RMS.<br />

For trace (n = 1 to 4) the detector is set to QUASIPEAK.<br />

For trace (n = 1 to 4) the detector is set to AC VIDEO (ESIB-B1)<br />

The frequency sweep is controlled via the EXT TRIG/GATE connector.<br />

The instrument is not triggered in FREE RUN mode.<br />

The unit is configured for operation with external reference<br />

75 Ω The input impedance of the unit is set to 75 Ω.<br />

MAC<br />

PRN<br />

VIEW<br />

AVG<br />

MIX<br />

SID<br />

AID<br />

Macro recording active.<br />

A printout is taking place. PRN overwrites the enhancement label<br />

MAC.<br />

Trace (n = 1 to 4) is set to VIEW<br />

Trace (n = 1 to 4) is set AVERAGE<br />

The external mixer output is switched on (option FSE-B21).<br />

External mixer output: SIGNAL ID is switched on (option FSE-B21).<br />

External mixer output: AUTO ID is switched on (option FSE-B21).<br />

1088.7531.12 3.7 E-13